ÎÊÐ * 1 – 0.08 ÒÓ Ó 27.3-00214534-095:2017 |
Distribution fiber-optic cables with steel strength element, with an outer sheath of flame retardant polymer compound |
Mark formation: |
ÎÊÐ -[b] [c]1(1x[e])-0.08 |
[b] quantity of optical fibers in the cable, possible values |
• 1, 2 |
[c] type of optical fiber |
• A – single-mode with extended wavelength band (ITU-T G.652D, ITU-T G.657A1) |
• D - single-mode, not sensitive to losses on macro-bending (ITU-T G.657A2) |
[e] quantity of optical fibers in the module: |
• 1 ... 2 |
|
|
|
Order placing: sample of indication (corresponds to configuration pattern) |
ÎÊÐ-2A1(1x2)-0.08 • ÒÓ Ó 27.3-00214534-095:2017 |
|
|
|
Cables are used for: |
• in areas with exclusive fire safety requirements |
• for laying on the external walls of buildings and structures |
• for laying inside and between buildings, or between the main line and the building |
• for laying in cable trays, channels, cable ducts, pipes |
|
|
|
Cables are available in either gel-filled or dry construction |
The color of the optical fibers of the cable can be optional |
Cable length marking on cable sheath is possible |
|
|
|
Fire safety code in accordance with ÄÑÒÓ 4809:2007: ÏÁ103122000 |
Products of this mark meet the requirements: |
• single wire cable flame retardance |
• toxicity class Tk3 of the combustion products of nonmetallic elements (toxicity index over 120 g/m3) |
• class ÄÒê1 on smoke-forming ability by smouldering of non-metallic elements (coefficient of smoke formation from 50 to 500 m2/kg) |
• class ÄÏê2 on smoke-forming ability by combustion (minimum luminous flux more than 60 %) |
• corrosive class Êê2 of combustion products of non-metallic elements (the number of halogen hydrides less than 150 mg/g, pH more than 4.3, specific conductivity less than 10 µS/mm) |