ÎÏÒ * 12 – 8 ÒÓ Ó 31.3-00214534-047:2005 |
Fiber optic overhead module-core cables, with polyethylene outer sheath |
Mark formation: |
ÎÏÒ-[a]-[b] [c]12(12x[e])-8 |
[a] central strength element |
• C – steel |
• No marks – dielectric |
[b] quantity of optical fibers in the cable, possible values |
• 72, 96, 120, 144, 156, 168, 180, 192 |
[c] type of optical fiber |
• E – single-mode (ITU-T G.652B) |
• A – single-mode with extended wavelength band (ITU-T G.652D, ITU-T G.657A1) |
• C – single-mode with non-zero shifted dispersion (ITU-T G.655) |
• M – multimode with core and sheath diameter ratio 50 : 125 mm (ITU-T G.651) |
• B – multimode with core and sheath diameter ratio 62.5 : 125 mm (IEC 60793-2) |
[e] quantity of optical fibers in the module: |
• 1 ... 16 |
|
|
|
Manufacturing of cables in climate version F is possible |
Manufacturing of cables with steel strength element is possible |
Manufacturing of cables with armouring (aramid yarns and/or corrugated steel tape) is possible |
Manufacturing of cables with steel or dielectric wire rope (glass fiber rod) is possible |
Manufacturing of cables with flame-retardant polymer compound outer sheath is possible |
It is possible to manufacture cables with gel-filled core or dry core (with water-blocking yarns and tapes) |
It is possible to manufacture cables with a number of core elements up to and including 18 |
|
|
|
Order placing: sample of indication (corresponds to configuration pattern) |
ÎÏÒ-120A12(12x10)-8 • ÒÓ Ó 31.3-00214534-047:2005 |
|
|
|
Cables are used for: |
• suspensions and operation at supports of aerial contact-lines, urban electric transport and aerial power transmission lines under impact of wind, ice or their combination loads |