ÎÁãÏí * 6 – 3.5 ÒÓ Ó 31.3-00214534-036-2004 |
Fiber optic module-core cables, corrugated steel-tape armoured, with polymer compound flame-retardant outer sheath |
Mark formation: |
ÎÁãÏí-[a]-[b] [c]6([d]x[e]+[f])-3.5 |
[a] central strength element |
• C – steel |
• No marks – dielectric |
[b] quantity of optical fibers in the cable, possible values |
• 4, 6, 8, 10, 12, 16, 18, 20, 22, 24, 28, 30, 32, 36, 40, 48, 60, 72, 78, 84, 90, 96 |
[c] type of optical fiber |
• E – single-mode (ITU-T G.652B) |
• A – single-mode with extended wavelength band (ITU-T G.652D, ITU-T G.657A1) |
• C – single-mode with non-zero shifted dispersion (ITU-T G.655) |
• M – multimode with core and sheath diameter ratio 50 : 125 mm (ITU-T G.651) |
• B – multimode with core and sheath diameter ratio 62.5 : 125 mm (IEC 60793-2) |
[d] 1 ... 6 – number of optical modules in cable |
[e] quantity of optical fibers in the module: |
• 1 ... 16 |
(f) quantity of insulated copper conductors in cable |
Optical modules are completed with string fillers up to total number of core elements |
|
|
|
Manufacturing of cables with two copper insulated remote power conductors instead of two string fillers is possible |
Manufacturing of cables in climate version F is possible |
Manufacturing of cables with steel strength element is possible |
Manufacturing of cables with dielectric armour (of glass fiber rod) is possible |
It is possible to manufacture cables with gel-filled core or dry core (with water-blocking yarns and tapes) |
It is possible to manufacture cables with a number of core elements up to and including 18 |
|
|
|
Order placing: sample of indication (corresponds to configuration pattern) |
ÎÁãÏí-36A6(6x6)-3.5 • ÒÓ Ó 31.3-00214534-036-2004 |
|
|
|
Cables are used for: |
• installation in pipes (including air installation method), blocks, collectors at risk of damage by rodents, as well as in soil by mechanical method |
• in areas with exclusive fire safety requirements |
|
|
|
Fire safety code in accordance with ÄÑÒÓ 4809:2007: ÏÁ130122000 |
Products of this mark meet the requirements: |
• single wire cable flame retardance |
• bunched cable flame retardance category B |
• class ÄÒê1 on smoke-forming ability by smouldering of non-metallic elements (coefficient of smoke formation from 50 to 500 m2/kg) |
• class ÄÏê2 on smoke-forming ability by combustion (minimum luminous flux more than 60 %) |
• corrosive class Êê2 of combustion products of non-metallic elements (the number of halogen hydrides less than 150 mg/g, pH more than 4.3, specific conductivity less than 10 µS/mm) |