ÎÁãÏ * 5 – 2.7 ÒÓ Ó 31.3-00214534-036-2004 |
Fiber optic module-core cables, corrugated steel-tape armoured, with polyethylene outer sheath |
Mark formation: |
ÎÁãÏ-[a]-[b] [c]5([d]x[e]+[f])-2.7 |
[a] central strength element |
• C – steel |
• No marks – dielectric |
[b] quantity of optical fibers in the cable, possible values |
• 8, 14, 16, 18, 20, 24, 26, 28, 30, 32, 36, 40, 48, 60, 65, 70, 75, 80 |
[c] type of optical fiber |
• E – single-mode (ITU-T G.652B) |
• A – single-mode with extended wavelength band (ITU-T G.652D, ITU-T G.657A1) |
• C – single-mode with non-zero shifted dispersion (ITU-T G.655) |
• M – multimode with core and sheath diameter ratio 50 : 125 mm (ITU-T G.651) |
• B – multimode with core and sheath diameter ratio 62.5 : 125 mm (IEC 60793-2) |
[d] 2 ... 5 – number of optical modules in cable |
[e] quantity of optical fibers in the module: |
• 1 ... 16 |
(f) quantity of insulated copper conductors in cable |
Optical modules are completed with string fillers up to total number of core elements |
|
|
|
Manufacturing of cables with two copper insulated remote power conductors instead of two string fillers is possible |
Manufacturing of cables in climate version F is possible |
Manufacturing of cables with steel strength element is possible |
Manufacturing of cables with dielectric armour (of glass fiber rod) is possible |
It is possible to manufacture cables with gel-filled core or dry core (with water-blocking yarns and tapes) |
It is possible to manufacture cables with a number of core elements up to and including 18 |
|
|
|
Order placing: sample of indication (corresponds to configuration pattern) |
ÎÁãÏ-18A5(3x6+2)-2.7 • ÒÓ Ó 31.3-00214534-036-2004 |
|
|
|
Cables are used for: |
• installation in pipes (including air installation method), blocks, collectors at risk of damage by rodents, as well as in soil by mechanical method |