1
2
3
4
5
6
 
ÎÏí * 6 – 3.5
ÒÓ Ó 31.3-00214534-036-2004
Fiber optic module-core cables with polymer compound flame-retardant outer sheath
Mark formation:
ÎÏí-[a]-[b] [c]6([d]x[e]+[f])-3.5
[a] central strength element
• C – steel
• No marks – dielectric
[b] quantity of optical fibers in the cable, possible values
• 4, 6, 8, 10, 12, 16, 18, 20, 22, 24, 28, 30, 32, 36, 40, 48, 60, 72, 78, 84, 90, 96
[c] type of optical fiber
• E – single-mode (ITU-T G.652B)
• A – single-mode with extended wavelength band (ITU-T G.652D, ITU-T G.657A1)
• C – single-mode with non-zero shifted dispersion (ITU-T G.655)
• M – multimode with core and sheath diameter ratio 50 : 125 mm (ITU-T G.651)
• B – multimode with core and sheath diameter ratio 62.5 : 125 mm (IEC 60793-2)
[d] 1 ... 6 – number of optical modules in cable
[e] quantity of optical fibers in the module:
• 1 ... 16
(f) quantity of insulated copper conductors in cable
Optical modules are completed with string fillers up to total number of core elements
Manufacturing of cables with two copper insulated remote power conductors instead of two string fillers is possible
Manufacturing of cables in climate version F is possible
Manufacturing of cables with steel strength element is possible
Manufacturing of cables, sealed with alumopolymer tape is possible (for laying in partially flooded premises
It is possible to manufacture cables with gel-filled core or dry core (with water-blocking yarns and tapes)
It is possible to manufacture cables with a number of core elements up to and including 18
Order placing: sample of indication (corresponds to configuration pattern)
ÎÏí-60A6(5x12)-3.5 • ÒÓ Ó 31.3-00214534-036-2004
Cables are used for:
• installation in cable ducts, blocks, pipes, protection polyethylene pipes (including air installation method), without risk of damage by rodents
• in areas with exclusive fire safety requirements
Fire safety code in accordance with ÄÑÒÓ 4809:2007: ÏÁ101122000
Products of this mark meet the requirements:
• single wire cable flame retardance
• toxicity class Tk1 of the combustion products of nonmetallic elements (toxicity index from 13 up to 40 g/m3)
• class ÄÒê1 on smoke-forming ability by smouldering of non-metallic elements (coefficient of smoke formation from 50 to 500 m2/kg)
• class ÄÏê2 on smoke-forming ability by combustion (minimum luminous flux more than 60 %)
• corrosive class Êê2 of combustion products of non-metallic elements (the number of halogen hydrides less than 150 mg/g, pH more than 4.3, specific conductivity less than 10 µS/mm)